Please refer to the equipment manufacturer's instructions and the technical parameters of the heat transfer oil for specific operations. Regularly train operators to ensure safe and standardized execution.


Question Why should new equipment or systems that have been out of service for a long time be cleaned? 2021-09-26 09:56:03.756
Answer

New equipment or systems that have been out of use for a long time because of welding slag, rust, oil sludge and other impurities need to be thoroughly cleaned to remove welding slag, oil and other impurities.
Use special cleaning agent or low viscosity heat transfer oil to flush the pipeline to ensure that there is no residue.

Question Why is it important to check the sealing of new equipment or systems that have been out of service for a long time? 2021-09-26 09:55:48.484
Answer

New equipment or systems that have been out of service for a long period of time need to make sure that there are no leaks in the piping, valves, flanges, and other connections to ensure safe operation.
Pressure test (usually 1.5 times the working pressure) should be carried out after the first oil filling.

Question Confirmation of heat transfer oil system equipment 2021-09-26 09:55:32.609
Answer

Check whether the expansion tank, circulating pump, filter, oil storage tank and other equipment is normal.
Make sure the system valves, thermometers, pressure gauges, flow meters and other instruments are intact.

Question Why does heat transfer oil need to be dehydrated and vented (a critical step for first time use)? 2021-09-26 09:55:20.266
Answer

Newly injected or long-term storage of heat conduction oil, due to system residual water, heat conduction oil stored improperly into the water and so on need to dewatering and degassing operation. The first time to slowly warm up to 100 ~ 120 ° C, 180 ~ 230 ° C, each held for 8 ~ 12 hours, the discharge of water and low-boiling material to ensure that the water, low-boiling material in all the discharge in the rise to the use of temperature.
During the warming process, it is necessary to observe the exhaust situation several times to prevent the gas resistance from causing pressure fluctuations or oil spraying.

Question What is the process of starting up a heat transfer oil system? 2021-09-26 09:55:05.128
Answer

Start the circulating pump, make sure the oil circuit is smooth, pressure and flow rate are stable before igniting and heating.
Initial warming rate ≤ 20 ℃ / hour, to avoid local overheating.

< 123 >

Intellectual Property Rights StatementINTELLECTUAL PROPERTY RIGHTS STATEMENT

1、http://www.beifangzite.com/The copyright belongs to Shandong Beifang Zite Special Oil Co., Ltd., which is the only legal website for the company's external publicity.

2、Shandong Beifang Zite Special Oil Co., Ltd. independently owns the relevant intellectual property rights of the relevant content in the website (including but not limited to text, pictures, video materials, page design, arrangement, software, etc.).

3、

Image Name

is a registered trademark of Shandong Beifang Zite Special Oil Co., Ltd. and is protected by law. No one shall use it without authorization.

4、Except as otherwise provided by law, without the written permission of Shandong Beifang Zite Special Oil Co., Ltd., no one shall copy any content of the website or make a mirror image on a server not owned by Shandong Beifang Zite Special Oil Co., Ltd., or use it in any other way.

5、If any violation of the above statement causes losses to Shandong Beifang Zite Special Oil Co., Ltd., Shandong Beifang Zite Special Oil Co., Ltd. will pursue its legal liability in accordance with the law.

6、The final interpretation right of this statement belongs to Shandong Beifang Zite Special Oil Co., Ltd.