Please refer to the equipment manufacturer's instructions and the technical parameters of the heat transfer oil for specific operations. Regularly train operators to ensure safe and standardized execution.


Question What are the requirements for heat transfer oil storage? 2025-05-08 13:27:26.216
Answer

Sealed and stored in a cool and ventilated place, avoid direct sunlight.
Shelf life is generally 3 years, need to be used as soon as possible after opening.

Question Heat transfer oil system operation common problems to deal with 2025-05-08 13:27:02.426
Answer

1, The oil temperature rises abnormally check: circulating pump failure, whether the pipeline is clogged, etc., need to stop the furnace to check the pump, filter, dredge the pipeline and so on.
2, The system pressure fluctuations: the possible causes of system air intake, heat transfer oil vaporization, etc., need to cool down to a safe pressure to check the equipment exhaust and other processing.
3, Heat transfer oil leakage: cause of aging seals, welding cracks, etc., need to shut down to repair, replenish the oil before the pressure test to confirm the system seal.
4, Oil aging: because the heat transfer oil use time is too long, over-temperature operation, high-temperature oxidation, etc., need to replace the new oil, thoroughly clean the system.

Question What do I need to know about system refills and oil changes? 2025-05-08 13:25:51.156
Answer

Supplementary new oil must be of the same type as crude oil, and dewatering is required before adding.
Waste oil should be treated according to environmental protection requirements and dumping is prohibited.

Question How often should I test my heat transfer oil system for coking filtration? 2025-05-08 13:25:42.245
Answer

Filters are cleaned monthly to prevent impurities from clogging pipes.
Full testing of coking is required after 6,000 hours of system operation. Coking filter?

Question Should heat transfer oil be tested regularly? 2025-05-08 13:25:32.799
Answer

Heat transfer oil should be regularly sampled and tested: viscosity, acid value, flash point, residual carbon and other indicators.
Acid value > 0.5mg KOH / g or residual carbon > 1.5% need to consider changing the oil.

< 123 >

Intellectual Property Rights StatementINTELLECTUAL PROPERTY RIGHTS STATEMENT

1、http://www.beifangzite.com/The copyright belongs to Shandong Beifang Zite Special Oil Co., Ltd., which is the only legal website for the company's external publicity.

2、Shandong Beifang Zite Special Oil Co., Ltd. independently owns the relevant intellectual property rights of the relevant content in the website (including but not limited to text, pictures, video materials, page design, arrangement, software, etc.).

3、

Image Name

is a registered trademark of Shandong Beifang Zite Special Oil Co., Ltd. and is protected by law. No one shall use it without authorization.

4、Except as otherwise provided by law, without the written permission of Shandong Beifang Zite Special Oil Co., Ltd., no one shall copy any content of the website or make a mirror image on a server not owned by Shandong Beifang Zite Special Oil Co., Ltd., or use it in any other way.

5、If any violation of the above statement causes losses to Shandong Beifang Zite Special Oil Co., Ltd., Shandong Beifang Zite Special Oil Co., Ltd. will pursue its legal liability in accordance with the law.

6、The final interpretation right of this statement belongs to Shandong Beifang Zite Special Oil Co., Ltd.